Skip to content
Skip to main navigation
Skip to first column
Skip to second column
Electrical Engineers And Master Electricians (EEAME) Portal
...electrical tutorials, calculations, and references
Home
Forums
Tutorials
Standards News
ANSI / API / IEC / IEEE
IEC Members
IEC News
Contents
Opinions
News
To Do List
Evolution
Dictionary
Disclaimer
Downloads
Engineering Tools
Device Function Numbers
Contact
Search
Search Keyword:
Search
All words
Any words
Exact Phrase
Ordering:
Newest First
Oldest First
Most Popular
Alphabetical
Section/Category
Search Only:
Articles
Web Links
Contacts
Categories
Sections
News Feeds
Search Keyword
cable
Total: 25 results found.
Display #
5
10
15
20
25
30
50
100
All
1.
(AFX UK Focus) 2009-06-16 18:09 Italy may invest billions in Montenegro energy-min (Interactive Investor)
(News/Latest)
... said on Tuesday. After meeting Montenegrin Prime Minister Milo Djukanovic in the capital Podgorica, Scajola said "investors are also interested in installing an undersea electric power
cable
... ...
2.
JAXA Selects OKI Electric Cable's Long FPC for Its Probe to Test World's First Solar Power Sail (Business Wire via Yahoo! Finance)
(News/Latest)
KANAGAWA, Japan----OKI Electric
Cable
today announced that its 14 meter Flexible Printed Circuit was selected by Japan Aerospace Exploration Agency , to be used for their probe, "IKAROS*1," which is a ...
3.
Earth Fault-Loop Impedance Part 3
(References/Tutorials)
In Part 2, we did a simple calculation for the maximum length of the
cable
. We have not considered the internal impedance of the source, i.e. the transformer impedance. Likewise, we just consider the current ...
4.
Earth Fault-Loop Impedance Part 2
(References/Tutorials)
... -
cable
impedance is limiting the earth fault current, the only solution will be using a residual current (earth leakage) protection. It is not always advisable to have this solution though. There are ...
5.
Time-Current Curves with Excel IV
(References/Tutorials)
... 250A set @ 5IN Supply
Cable
Size : 35 mm2 PVC/PVC Primary Circuit Breaker (0.16 time multiplier) Rating : 160A Setting 1 : 800A @ 5IN Setting 2 : 1120A @ 7IN Power Transformer Rating: 2500 kVA, 11/0.415kV, ...
6.
Hign Voltage Switchgear Rated Insulation Level
(News/Blog)
... switching impulse voltage (Us) (when appli
cable
), and power-frequency voltage (Ud) shall be selected without crossing the horizontal marked lines. The rated insulation level is specified by the rated lightning ...
7.
Anniversary Challenge
(News/Blog)
... a year to our member who are able to provide the first correct answer to our challenge question. The Challenge: The photos are taken from the
cable
compartment of an 11KV Switchgear. The installation ...
8.
Variable Speed Drive vs Soft Starter
(News/Blog)
Selecting the right equipment to perform the right task during design is a tedious job. A very good example is the variable speed drive (VSD) versus Soft Starter(SS). On low capacity drives (
9.
IEEE Std 242 Protection and Coordination
(References/IEEE)
... other appli
cable
codes and regulations relating to human safety. ...
10.
IEEE Std 142 Grounding Power Systems
(References/IEEE)
... the frames and enclosures of electric apparatus, such as motors, switchgear, transformers, buses,
cable
s, conduits, building frames, and portable equipment, to a ground system is addressed. The fundamentals ...
11.
Cable Calculation and Selection Worksheet
(References/Tutorials)
As the final article on voltage drop and
cable
selection series, I am now providing a complete worksheet for
cable
selection based on the IEC standards 60228 and 60364-5-54. I created the worksheet in ...
12.
A New Environment
(News/Blog)
... for load calculations, load flow analysis,
cable
s sizing calculations, etc., there were none. Then I said to myself, I will be having a tough time here. A good tip to those people who are transferring ...
13.
Moving On
(News/Blog)
... upcoming articles will be:
Cable
short circuit withstand
Cable
selection economy And many more. . . ...
14.
Cable Operating Temperature
(References/Tutorials)
Electrical design requires selecting the
cable
with the correct temperature rating. Designers tend to select the
cable
with the highest temperature rating, this is not acceptable as the first cost of the ...
15.
Voltage Drop Calculation - Part 3
(References/Tutorials)
In our example in Voltage Calculation - Part 2, we have only considered a single
cable
and checked only the voltage drop at starting. In actual practice, we shall be comparing several
cable
sizes, selecting ...
16.
Voltage Drop Calculation - Part 2
(References/Tutorials)
... of what you have already done or currently doing in your design. We shall be presenting an IEC standard equipment in our sample calculation. A 120 mm2 3core XLPE insulated
cable
120m in length ...
17.
Voltage Drop Calculation
(References/Tutorials)
This article is the first of a series in the selection of electrical
cable
s.
Cable
selection is an important part of electrical installation design. Selecting the correct size of
cable
could lower ...
18.
Earthing and Bonding
(News/Latest)
...
cable
s, a conductive sheath (usually metallic) applied over the insulation of a conductor or conductors, for the purpose of providing means to reduce coupling between the conductors so shielded and other ...
19.
IEC 60079 - General Requirements
(Standards News/IEC)
... ambient temperature range shall then be stated by the manufacturer. The marking shall then include either the symbol Ta or Tamb together with the special range of ambient temperatures or, if this is impracti
cable
, ...
20.
Classification of Hazardous Areas
(Standards News/IEC)
... because the flammability characteristics of mists are not always predictable. Whilst it can be difficult to decide upon the type and extent of zones, the criteria appli
cable
to gases and vapours will, ...
21.
To be or not to be
(News/Blog)
... To be or not to be influenced by the client to heed to selecting equipment not suitable to the appli
cable
because it cheap. The list goes on... In the first world, experience of this nature is beyond ...
22.
IEC 60364 and ANSI/NFPA 70
(Standards News/General)
... of premises wiring systems and equipment. Appli
cable
to wiring systems of premises for residential, commercial, and industrial use. Hazardous locations (explosive atmospheres) are covered only in the ...
23.
Merging Standards
(Standards News/General)
... An example of this is joining an IEC
cable
to an NEC
cable
. There are no exact equivalent of
cable
sizes for either standard. It will either be one or the other. Another good example for this will be the ...
24.
To Do List
('Uncategorised Content')
The Filipino Engineer will be adding the following contents soon. ANSI, NEMA, UL Standards on the Electrical Standards List Sample documents such as Load Calculations
Cable
Sizing Calculations ...
25.
Grounding of Power Systems
(References/IEEE)
... Connecting the frames and enclosures of electric apparatus, such as motors, switchgear, transformers, buses,
cable
s conduits, building frames, and portable equipment, to a ground system is addressed. The ...
Our Ads
Our Sponsors
Feedjit Live Blog Stats